Solution

Modular FastIns Clean Laboratory

Modular FastIns Clean Laoratory's feature is simply construction, easy installation, low cost, low maintenance cost and wide application. The most important indicator of a clean laboratory is the concentration of dust particles, which is guaranteed to be clean area from the perspective of reducing and controlling the concentration of dust particles.

  • Modular FastIns Clean Laboratory

    Modular FastIns Clean Laoratory's feature is simply construction, easy installation, low cost, low maintenance cost and wide application. The most important indicator of a clean laboratory is the concentration of dust particles, which is guaranteed to be clean area from the perspective of reducing and controlling the concentration of dust particles.

  • Modular FastIns Clean Laboratory

    Modular FastIns Clean Laoratory's feature is simply construction, easy installation, low cost, low maintenance cost and wide application. The most important indicator of a clean laboratory is the concentration of dust particles, which is guaranteed to be clean area from the perspective of reducing and controlling the concentration of dust particles.

  • Basic measures

    Maintaining indoor positive pressure, ensuring the effectiveness of high-efficiency filters and sealing of maintenance structures, and setting up measures such as human and material purification facilities to prevent direct intrusion of outdoor pollution;
    Prevent dust accumulation by optimizing the inner surface structure of the building and the design of equipment piping;
    Improve the level of process automation, control pollution sources, and reduce the amount of Hui dust generated by rationally planning the flow of people, logistics, and materials;
    Rationally plan the airflow organization to effectively and quickly eliminate the dust generated indoors.

    SPF Laboratory

    Animal experiments refer to the use of animals for scientific research in the laboratory in order to obtain new knowledge about biology, medicine or to solve specific problems. SPF laboratories usually use ABSL-1, ABSL-2, ABSL-3, and ABSL-4 to represent the appropriate level.
    SPF laboratory is strictly in accordance with national standards, which chooses environmentally-friendly and durable building materials that are easy to clean and maintain.

  • SPF Laboratory

    Animal experiments refer to the use of animals for scientific research in the laboratory in order to obtain new knowledge about biology, medicine or to solve specific problems. SPF laboratories usually use ABSL-1, ABSL-2, ABSL-3, and ABSL-4 to represent the appropriate level.
    SPF laboratory is strictly in accordance with national standards, which chooses environmentally-friendly and durable building materials that are easy to clean and maintain.

  • SPF Laboratory

    Animal experiments refer to the use of animals for scientific research in the laboratory in order to obtain new knowledge about biology, medicine or to solve specific problems. SPF laboratories usually use ABSL-1, ABSL-2, ABSL-3, and ABSL-4 to represent the appropriate level.
    SPF laboratory is strictly in accordance with national standards, which chooses environmentally-friendly and durable building materials that are easy to clean and maintain.

  • Features

    Wall, ceiling and door would apply with 50mm thickness sandwich panel with special electrophoretic aluminum alloy profiles.
    Sound insulation ≥28dB(A), heat transfer coefficient of insulation board is 2.5W/m2K;
    Anti-static PVC floor for aseptic area and related areas.



    Constant Temp.&Humi. HVAC System

    The constant temperature and humidity air conditioning system consists of controller, human-machine interface, frequency converter, temperature sensor, temperature and humidity sensor, water valve actuator, damper actuator, high temperature circuit breaker and air pressure switch. The constant temperature and humidity laboratory is a specialized laboratory that requires the indoor temperature and humidity to meet the requirements of the test through special equipment and technical methods.

  • Constant Temp.&Humi. HVAC System

    The constant temperature and humidity air conditioning system consists of controller, human-machine interface, frequency converter, temperature sensor, temperature and humidity sensor, water valve actuator, damper actuator, high temperature circuit breaker and air pressure switch. The constant temperature and humidity laboratory is a specialized laboratory that requires the indoor temperature and humidity to meet the requirements of the test through special equipment and technical methods.

  • Constant Temp.&Humi. HVAC System

    The constant temperature and humidity air conditioning system consists of controller, human-machine interface, frequency converter, temperature sensor, temperature and humidity sensor, water valve actuator, damper actuator, high temperature circuit breaker and air pressure switch. The constant temperature and humidity laboratory is a specialized laboratory that requires the indoor temperature and humidity to meet the requirements of the test through special equipment and technical methods.

  • SOLUTION

    Design Concept: Reliable and Guaranteed, Energy-Saving Operating

    1. Specially design for operation theater energy-saving, space-saving;
    2. It’s a combination of purifying air conditioning, heating device and constant temperature & humidity control;
    3. Add VAV control system.

    Pure Water System

    There are large amount of pure water needed for various scientific research and scientific experiments inside the laboratory. The traditional mode is that each laboratory uses small water-making equipment to disperse water and supply water, which has been gradually eliminated. Nowadays, begining with the design and construction of the laboratory, it has adopted a centralized water supply method. In the experimental building, the impurities in the water were purified at a fixed location to meet the experimental requirements and the pipeline was used to connect several points of use to supply pure water, which called Central Ultrapure Water System.

  • Pure Water System

    There are large amount of pure water needed for various scientific research and scientific experiments inside the laboratory. The traditional mode is that each laboratory uses small water-making equipment to disperse water and supply water, which has been gradually eliminated. Nowadays, begining with the design and construction of the laboratory, it has adopted a centralized water supply method. In the experimental building, the impurities in the water were purified at a fixed location to meet the experimental requirements and the pipeline was used to connect several points of use to supply pure water, which called Central Ultrapure Water System.

  • Pure Water System

    There are large amount of pure water needed for various scientific research and scientific experiments inside the laboratory. The traditional mode is that each laboratory uses small water-making equipment to disperse water and supply water, which has been gradually eliminated. Nowadays, begining with the design and construction of the laboratory, it has adopted a centralized water supply method. In the experimental building, the impurities in the water were purified at a fixed location to meet the experimental requirements and the pipeline was used to connect several points of use to supply pure water, which called Central Ultrapure Water System.

  • SOLUTION

    Impurities:
    Particulate matter, colloidal substance, ionic substance, unreacted dissolved gas, microorganism, heat source, organic substance, residual disinfectant, etc.

    Biosafety Laboratory

    The biosafety laboratories are divided into four levels according to the degree of biohazard and the protective measures. Among them, the first level requirements for biosafety isolation are very low, and the fourth level is the highest. The corresponding level of biosafety laboratory is generally indicated by BSL-1, BSL-2, BSL-3, and BSL-4.

  • Biosafety Laboratory

    The biosafety laboratories are divided into four levels according to the degree of biohazard and the protective measures. Among them, the first level requirements for biosafety isolation are very low, and the fourth level is the highest. The corresponding level of biosafety laboratory is generally indicated by BSL-1, BSL-2, BSL-3, and BSL-4.

  • Biosafety Laboratory

    The biosafety laboratories are divided into four levels according to the degree of biohazard and the protective measures. Among them, the first level requirements for biosafety isolation are very low, and the fourth level is the highest. The corresponding level of biosafety laboratory is generally indicated by BSL-1, BSL-2, BSL-3, and BSL-4.

  • 5

  • 3

  • 2

  • 1

  • 4

  • SOLUTION

    Technical indicators of the biosafety laboratory:
    Secondary biosafety laboratories should implement a primary barrier or secondary barrier
    Level 3 and 4 biosafety laboratories should implement both primary and secondary barriers.

    Related products

    Pipeless Fume Hood

    Pipeless Fume Hood

    Pipeless Storage Cabinet

    Pipeless Storage Cabi...

    Fume Hood

    Fume Hood

    Explosion-Proof Cabinet

    Explosion-Proof Cabin...

    Fume Exhaust

    Fume Exhaust

    Individual Ventilated Cages

    IVC Cage

    Particle Counter

    Particle Counter

    Thermo-Hygrometer

    Thermo-Hygrometer

    Anemometer

    Anemometer

    Share
    Contact
    Message