A highly clean controlled environment centered on FFU (Fan Filter Unit); It is a good option to create a cleaner space within an existing normal room or a room with low-level of cleanliness. MCR can be a small as several square meters and as big as several hundred square meters.
Advantages of modular clean room
A highly clean controlled environment centered on FFU (Fan Filter Unit); It is a good option to create a cleaner space within an existing normal room or a room with low-level of cleanliness. MCR can be a small as several square meters and as big as several hundred square meters.
Advantages of modular clean room
Airkey provides a whole modular clean room with all the accessories, including SUS frames, wall panels, ceiling grid, fan filter unit (FFU), control panel, light, diffuser, door, AC unit (if required) etc, a whole system that can be used directly after installation
Description:
1. T-GRID ceiling
2. FFU (with H14 filter)
3. Wall panels (acrylic/sandwich panel/PVC)
4. Diffuser / louvers
5. Control box
6. SUS304 frame / Aluminum frame
7. Air-tight door
Optional: air shower/pass box/clean bench/Air conditioning system and so on.
1. The overall area design layout of function room setting and area of the intravenous drug distribution center (room) should be compatible with the workload, and can ensure the division of the clean area, auxiliary work area and living area, and the flow of people and logistics between different areas The direction of entry and exit is reasonable. There should be corresponding facilities to prevent cross-contamination between areas of different cleanliness levels.
2. Intravenous medication distribution center (room) should be located in a quiet area with little personnel flow, and it is convenient for communication with medical staff and delivery of finished products. The installation location should be far away from various sources of pollution, and it is forbidden to install in the basement or semi-basement. The surrounding environment, road surface, vegetation, etc. will not cause pollution to the intravenous drug preparation process. The air intake of the clean area should be set in a clean and pollution-free area within 30 meters, and the height from the ground should not be less than 3 meters.
3. The clean area and auxiliary work area of the intravenous drug preparation center (room) should have appropriate space for the installation of corresponding facilities and equipment; the clean area should contain the primary dressing, secondary dressing and deployment operation room; It is suitable for functional rooms such as storage of medicines and materials, printing by reviewing party, preparation of drug placement, finished product verification, packaging and general dressing.
5. The clean area of the intravenous drug preparation center (room) should be equipped with monitoring equipment such as temperature, humidity, air pressure and ventilation facilities to maintain the temperature of the intravenous drug preparation room at 18C~26"C and the relative humidity of 40%~65%. The amount of fresh air is sent in.
6. The cleanliness standards of the clean area of the intravenous drug compounding center (room) should meet the relevant national regulations, and can only be put into use after passing the test by the legal testing department.
The clean level requirements of each functional room:
① One-time dressing room and laundry room are class 100,000;
② The second dressing room and the medicine mixing and mixing operation room are class 10,000;
③ The laminar flow operation platform is class 100.
The PICU is the section of the hospital that provides sick children with the highest level of medical care. What makes the PICU different from other parts of the hospital is that this area allows intensive nursing care and continuous monitoring of things like heart rate, breathing and blood pressure.
Any child who is seriously ill, needs intensive care and whose medical needs can't be met on the hospital's main medical floors goes to the PICU, such as:
The PICU is the section of the hospital that provides sick children with the highest level of medical care. What makes the PICU different from other parts of the hospital is that this area allows intensive nursing care and continuous monitoring of things like heart rate, breathing and blood pressure.
Any child who is seriously ill, needs intensive care and whose medical needs can't be met on the hospital's main medical floors goes to the PICU, such as:
1. The building decoration of the ward must follow the general principles of no dust production, no dust accumulation, corrosion resistance, moisture-proof, mildew-proof and anti-static, easy to clean and meet the fire protection requirements. It should have good ventilation and lighting conditions, equipped with air conditioning and purification systems, so that the air conditioning and purification of each single room can be independently controlled to achieve independent control of indoor temperature and humidity. The temperature should be 24 ~ 26 ℃, and the humidity should be 50% ~ 60%.
2. Auxiliary rooms: Basic auxiliary rooms include physician's office and director's office. Staff lounge, central workstation, treatment room, dispensing room, instrument room, dressing room, clean room, sewage treatment room, duty room, washroom, etc. . The conditional PICU can be equipped with other auxiliary rooms, including classrooms, family reception rooms, laboratories, and nutrition preparation rooms. The ratio of auxiliary room to ward area should reach 1.5: 1 or more.